Changeset 587 in ETALON


Ignore:
Timestamp:
Apr 28, 2016, 5:35:49 PM (8 years ago)
Author:
malovyts
Message:

Removed vertical lines in table

Location:
papers/2016_IPAC/2016_IPAC_Malovytsia_ModelComparison
Files:
2 edited

Legend:

Unmodified
Added
Removed
  • papers/2016_IPAC/2016_IPAC_Malovytsia_ModelComparison/MOPMB004.tex

    r585 r587  
    111111        \begin{figure}
    112112                \includegraphics[width=0.5\textwidth]{MOPMB004f1.png}
    113                 \caption{Definition of the variables used in this paper}
     113                \caption{Definition of the variables used in this paper.}
    114114                \label{fig:geom1}
    115115        \end{figure}
     
    209209                \label{tab:SPESO_E203}
    210210                \small
    211                 \begin{tabular}{|m{6mm}|m{8mm}|m{7mm}|m{6mm}|m{30mm}|}
    212                         \hline
    213                         Symb.           & SPESO & E203  & Units & Description\\ \hline
    214                         $\gamma$        & 200   & 4$\times$10\textsuperscript{4}        & 1             & The Lorentz factor (E=100~MeV)        \\ \hline
    215                         $ d $           & 10    & 0.25  & mm            & The grating period                    \\ \hline
    216                         $ a $           & 7.5   & 0.187 & mm            & The width of one strip                \\ \hline
    217                         $ R_0 $         & 310   & 220   & mm            & The distance between detector and grating\\ \hline
    218                         $ L $           & 90    & 40    & mm            & The length of the grating             \\ \hline
    219                         $ M $           & 20    & 20    & mm            & The width of the grating              \\ \hline
    220                         $ h $           & 5             & 1             & mm            & The beam-grating separation   \\ \hline
    221                         %$ n $          & 1             & 1             & 1                     & The order of the radiation    \\ \hline
    222                         $ \theta_0 $& 30        & 30    & deg           & The blaze angle                               \\ \hline
     211                \begin{tabular}{m{6mm} m{8mm} m{7mm} m{6mm} m{30mm} }
     212                        \toprule
     213                        Symb.           & SPESO & E203  & Units & Description\\
     214                        \midrule
     215                        $\gamma$        & 200   & 4$\times$10\textsuperscript{4}        & 1             & The Lorentz factor (E=100~MeV)        \\
     216                        $ d $           & 10    & 0.25  & mm            & The grating period                    \\
     217                        $ a $           & 7.5   & 0.187 & mm            & The width of one strip                \\
     218                        $ R_0 $         & 310   & 220   & mm            & The distance between detector and grating\\
     219                        $ L $           & 90    & 40    & mm            & The length of the grating             \\
     220                        $ M $           & 20    & 20    & mm            & The width of the grating              \\
     221                        $ h $           & 5             & 1             & mm            & The beam-grating separation   \\
     222                        $ \theta_0 $& 30        & 30    & deg           & The blaze angle                               \\
    223223                        $ C_1' $        & 400   & 6395  & mm\textsuperscript{-3} & The normalization constant for the RRR model \\
    224                         \hline
     224                        \bottomrule
    225225                \end{tabular}
    226226                \normalsize
Note: See TracChangeset for help on using the changeset viewer.