source: trunk/documents/UserDoc/DocBookUsersGuides/ForApplicationDeveloper/xml/FAQ/physicsAndCuts.xml @ 1288

Last change on this file since 1288 was 1208, checked in by garnier, 15 years ago

CVS update

File size: 2.2 KB
Line 
1<!-- ******************************************************** -->
2<!--                                                          -->
3<!--  [History]                                               -->
4<!--    1st version created:  Katsuya Amako, Dec-2006         -->
5<!--                                                          -->
6<!-- ******************************************************** -->
7
8
9<!-- ********************* QandA Section ******************** -->
10<section id="qanda.PhysicsCuts">
11<title>
12Physics and cuts
13</title>
14
15<qandaset defaultlabel="qanda">
16
17
18<!-- ******* QandA Entry ******** -->
19<qandaentry  id="qanda.PhysicsCuts.HowProdCuts">
20
21<question><para>
22  How do production cuts (in range) work in Geant4 ? Are they also used
23  in tracking ? If a particle has an energy lower than the converted cut
24  in energy for the given material and the distance to the next boundary
25  is smaller than the cut in range, is the particle killed ?
26</para></question>
27
28<answer><para>
29  Geant4 does <emphasis role="bold">NOT</emphasis> have a "tracking cut".
30  The toolkit's default behaviour is to track particles down to zero range
31  (i.e. zero energy). Of course, it is possible for the user to create and
32  register a process that kills particles below a certain energy or range;
33  this is however <emphasis role="bold">NOT</emphasis> provided by default
34  in Geant4. So there's <emphasis role="bold">NO</emphasis> "tracking cut".
35  For example, suppose a particle that is nearing zero energy will at some
36  point be proposed by its Ionisation process to undergo one final step,
37  from its current energy down to zero energy. This is still only a
38  proposal. If during this step the particle crosses a boundary, then the
39  transportation will limit the step at a length smaller than the
40  Ionisation -- so the particle will still see and cross the relevant
41  boundary, and another step will occur on the other side of that boundary.
42  In summary the "production threshold" range and its equivalent in energy
43  are not utilised as a "tracking cut". A particle is not abandoned by
44  Geant4 below a certain range/energy unless the user registers a process
45  to do this by him/her-self.
46</para></answer>
47
48</qandaentry>
49
50
51</qandaset>
52</section>
Note: See TracBrowser for help on using the repository browser.