[904] | 1 | /control/manual /run |
---|
| 2 | Command directory path : /run/ |
---|
| 3 | |
---|
| 4 | |
---|
| 5 | Guidance : |
---|
| 6 | Run control commands. |
---|
| 7 | |
---|
| 8 | Sub-directories : |
---|
| 9 | /run/particle/ Commands for G4VUserPhysicsList. |
---|
| 10 | Commands : |
---|
| 11 | initialize * Initialize G4 kernel. |
---|
| 12 | beamOn * Start a Run. |
---|
| 13 | verbose * Set the Verbose level of G4RunManager. |
---|
| 14 | dumpRegion * Dump region information. |
---|
| 15 | dumpCouples * Dump material-cuts-couple information. |
---|
| 16 | optimizeGeometry * Set the optimization flag for geometry. |
---|
| 17 | breakAtBeginOfEvent * Set a break point at the begining of every event. |
---|
| 18 | breakAtEndOfEvent * Set a break point at the end of every event. |
---|
| 19 | abort * Abort current run processing. |
---|
| 20 | abortCurrentEvent * Abort currently processing event. |
---|
| 21 | geometryModified * Force geometry to be closed again. |
---|
| 22 | cutoffModified * Force closssection tables to be calculated again. |
---|
| 23 | randomNumberStatusDirectory * Define the directory name of the rndm status files. |
---|
| 24 | storeRandomNumberStatus * The randomNumberStatus will be saved at : |
---|
| 25 | restoreRandomNumberStatus * Reset the status of the rndm engine from a file. |
---|
| 26 | setCut * Set default cut value |
---|
| 27 | setCutForRegion * Set cut value for a region |
---|
| 28 | |
---|
| 29 | |
---|
| 30 | Command /run/initialize |
---|
| 31 | Guidance : |
---|
| 32 | Initialize G4 kernel. |
---|
| 33 | |
---|
| 34 | |
---|
| 35 | |
---|
| 36 | Command /run/beamOn |
---|
| 37 | Guidance : |
---|
| 38 | Start a Run. |
---|
| 39 | If G4 kernel is not initialized, it will be initialized. |
---|
| 40 | Default number of events to be processed is 1. |
---|
| 41 | The second and third arguments can be used for |
---|
| 42 | executing a macro file at the end of each event. |
---|
| 43 | If the second argument, i.e. name of the macro |
---|
| 44 | file, is given but the third argument is not, |
---|
| 45 | the macro file will be executed for all of the |
---|
| 46 | event. |
---|
| 47 | If the third argument (nSelect) is given, the |
---|
| 48 | macro file will be executed only for the first |
---|
| 49 | nSelect events. |
---|
| 50 | |
---|
| 51 | Parameter : numberOfEvent |
---|
| 52 | Parameter type : i |
---|
| 53 | Omittable : True |
---|
| 54 | Default value : 1 |
---|
| 55 | Parameter range : numberOfEvent >= 0 |
---|
| 56 | |
---|
| 57 | Parameter : macroFile |
---|
| 58 | Parameter type : s |
---|
| 59 | Omittable : True |
---|
| 60 | Default value : ***NULL*** |
---|
| 61 | |
---|
| 62 | Parameter : nSelect |
---|
| 63 | Parameter type : i |
---|
| 64 | Omittable : True |
---|
| 65 | Default value : -1 |
---|
| 66 | Parameter range : nSelect>=-1 |
---|
| 67 | |
---|
| 68 | |
---|
| 69 | |
---|
| 70 | Command /run/verbose |
---|
| 71 | Guidance : |
---|
| 72 | Set the Verbose level of G4RunManager. |
---|
| 73 | 0 : Silent (default) |
---|
| 74 | 1 : Display main topics |
---|
| 75 | 2 : Display main topics and run summary |
---|
| 76 | Range of parameters : level >=0 && level <=2 |
---|
| 77 | |
---|
| 78 | Parameter : level |
---|
| 79 | Parameter type : i |
---|
| 80 | Omittable : True |
---|
| 81 | Default value : 0 |
---|
| 82 | |
---|
| 83 | |
---|
| 84 | |
---|
| 85 | Command /run/dumpRegion |
---|
| 86 | Guidance : |
---|
| 87 | Dump region information. |
---|
| 88 | In case name of a region is not given, all regions will be displayed. |
---|
| 89 | |
---|
| 90 | Parameter : regionName |
---|
| 91 | Parameter type : s |
---|
| 92 | Omittable : True |
---|
| 93 | Default value : **ALL** |
---|
| 94 | |
---|
| 95 | |
---|
| 96 | |
---|
| 97 | Command /run/dumpCouples |
---|
| 98 | Guidance : |
---|
| 99 | Dump material-cuts-couple information. |
---|
| 100 | Note that material-cuts-couple information is updated |
---|
| 101 | after BeamOn has started. |
---|
| 102 | |
---|
| 103 | |
---|
| 104 | |
---|
| 105 | Command /run/optimizeGeometry |
---|
| 106 | Guidance : |
---|
| 107 | Set the optimization flag for geometry. |
---|
| 108 | If it is set to TRUE, G4GeometryManager will optimize |
---|
| 109 | the geometry definitions. |
---|
| 110 | GEANT4 is initialized with this flag as TRUE. |
---|
| 111 | |
---|
| 112 | Parameter : optimizeFlag |
---|
| 113 | Parameter type : b |
---|
| 114 | Omittable : True |
---|
| 115 | Default value : 1 |
---|
| 116 | |
---|
| 117 | |
---|
| 118 | |
---|
| 119 | Command /run/breakAtBeginOfEvent |
---|
| 120 | Guidance : |
---|
| 121 | Set a break point at the begining of every event. |
---|
| 122 | |
---|
| 123 | Parameter : flag |
---|
| 124 | Parameter type : b |
---|
| 125 | Omittable : True |
---|
| 126 | Default value : 1 |
---|
| 127 | |
---|
| 128 | |
---|
| 129 | |
---|
| 130 | Command /run/breakAtEndOfEvent |
---|
| 131 | Guidance : |
---|
| 132 | Set a break point at the end of every event. |
---|
| 133 | |
---|
| 134 | Parameter : flag |
---|
| 135 | Parameter type : b |
---|
| 136 | Omittable : True |
---|
| 137 | Default value : 1 |
---|
| 138 | |
---|
| 139 | |
---|
| 140 | |
---|
| 141 | Command /run/abort |
---|
| 142 | Guidance : |
---|
| 143 | Abort current run processing. |
---|
| 144 | If softAbort is false (default), currently processing event will be immediately aborted, |
---|
| 145 | while softAbort is true, abortion occurs after processing the current event. |
---|
| 146 | |
---|
| 147 | Parameter : softAbort |
---|
| 148 | Parameter type : b |
---|
| 149 | Omittable : True |
---|
| 150 | Default value : 0 |
---|
| 151 | |
---|
| 152 | |
---|
| 153 | |
---|
| 154 | Command /run/abortCurrentEvent |
---|
| 155 | Guidance : |
---|
| 156 | Abort currently processing event. |
---|
| 157 | |
---|
| 158 | |
---|
| 159 | |
---|
| 160 | Command /run/geometryModified |
---|
| 161 | Guidance : |
---|
| 162 | Force geometry to be closed again. |
---|
| 163 | This command must be applied |
---|
| 164 | if geometry has been modified after the |
---|
| 165 | first initialization (or BeamOn). |
---|
| 166 | |
---|
| 167 | |
---|
| 168 | |
---|
| 169 | Command /run/cutoffModified |
---|
| 170 | Guidance : |
---|
| 171 | Force closssection tables to be calculated again. |
---|
| 172 | This command must be applied |
---|
| 173 | if cutoff value(s) have been modified after the |
---|
| 174 | first initialization (or BeamOn). |
---|
| 175 | |
---|
| 176 | |
---|
| 177 | |
---|
| 178 | Command /run/randomNumberStatusDirectory |
---|
| 179 | Guidance : |
---|
| 180 | Define the directory name of the rndm status files. |
---|
| 181 | Directory must be creates before storing the files. |
---|
| 182 | |
---|
| 183 | Parameter : fileName |
---|
| 184 | Parameter type : s |
---|
| 185 | Omittable : True |
---|
| 186 | Default value : ./ |
---|
| 187 | |
---|
| 188 | |
---|
| 189 | |
---|
| 190 | Command /run/storeRandomNumberStatus |
---|
| 191 | Guidance : |
---|
| 192 | The randomNumberStatus will be saved at : |
---|
| 193 | begining of run (currentRun.rndm) and begining of event (currentEvent.rndm) |
---|
| 194 | |
---|
| 195 | Parameter : flag |
---|
| 196 | Parameter type : i |
---|
| 197 | Omittable : True |
---|
| 198 | Default value : 1 |
---|
| 199 | |
---|
| 200 | |
---|
| 201 | |
---|
| 202 | Command /run/restoreRandomNumberStatus |
---|
| 203 | Guidance : |
---|
| 204 | Reset the status of the rndm engine from a file. |
---|
| 205 | See CLHEP manual for detail. |
---|
| 206 | The engine status must be stored beforehand. |
---|
| 207 | Directory of the status file should be set by /random/setDirectoryName. |
---|
| 208 | |
---|
| 209 | Parameter : fileName |
---|
| 210 | Parameter type : s |
---|
| 211 | Omittable : True |
---|
| 212 | Default value : currentRun.rndm |
---|
| 213 | |
---|
| 214 | |
---|
| 215 | |
---|
| 216 | Command /run/setCut |
---|
| 217 | Guidance : |
---|
| 218 | Set default cut value |
---|
| 219 | Range of parameters : cut >0.0 |
---|
| 220 | |
---|
| 221 | Parameter : cut |
---|
| 222 | Parameter type : d |
---|
| 223 | Omittable : False |
---|
| 224 | Default value : 1 |
---|
| 225 | |
---|
| 226 | Parameter : Unit |
---|
| 227 | Parameter type : s |
---|
| 228 | Omittable : True |
---|
| 229 | Default value : mm |
---|
| 230 | Candidates : pc km m cm mm mum nm Ang fm parsec kilometer meter centimeter millimeter micrometer nanometer angstrom fermi |
---|
| 231 | |
---|
| 232 | |
---|
| 233 | |
---|
| 234 | Command /run/setCutForRegion |
---|
| 235 | Guidance : |
---|
| 236 | Set cut value for a region |
---|
| 237 | |
---|
| 238 | Parameter : Region |
---|
| 239 | Parameter type : s |
---|
| 240 | Omittable : False |
---|
| 241 | |
---|
| 242 | Parameter : cut |
---|
| 243 | Parameter type : d |
---|
| 244 | Omittable : False |
---|
| 245 | Parameter range : cut >0.0 |
---|
| 246 | |
---|
| 247 | Parameter : Unit |
---|
| 248 | Parameter type : s |
---|
| 249 | Omittable : True |
---|
| 250 | Default value : mm |
---|
| 251 | Candidates : pc km m cm mm mum nm Ang fm parsec kilometer meter centimeter millimeter micrometer nanometer angstrom fermi |
---|
| 252 | |
---|
| 253 | Command directory path : /run/particle/ |
---|
| 254 | |
---|
| 255 | |
---|
| 256 | Guidance : |
---|
| 257 | Commands for G4VUserPhysicsList. |
---|
| 258 | |
---|
| 259 | Sub-directories : |
---|
| 260 | Commands : |
---|
| 261 | verbose * Set the Verbose level of G4VUserPhysicsList. |
---|
| 262 | setCut * Set default cut value |
---|
| 263 | dumpList * Dump List of particles in G4VUserPhysicsList. |
---|
| 264 | addProcManager * add process manager to specified particle type |
---|
| 265 | buildPhysicsTable * build physics table of specified particle type |
---|
| 266 | storePhysicsTable * Store Physics Table |
---|
| 267 | retrievePhysicsTable * Retrieve Physics Table |
---|
| 268 | setStoredInAscii * Switch on/off ascii mode in store/retreive Physics Table |
---|
| 269 | applyCuts * Set applyCuts flag for a particle. |
---|
| 270 | dumpCutValues * Dump a list of production threshold values in range and energy |
---|
| 271 | |
---|
| 272 | |
---|
| 273 | Command /run/particle/verbose |
---|
| 274 | Guidance : |
---|
| 275 | Set the Verbose level of G4VUserPhysicsList. |
---|
| 276 | 0 : Silent (default) |
---|
| 277 | 1 : Display warning messages |
---|
| 278 | 2 : Display more |
---|
| 279 | Range of parameters : level >=0 && level <=3 |
---|
| 280 | |
---|
| 281 | Parameter : level |
---|
| 282 | Parameter type : i |
---|
| 283 | Omittable : True |
---|
| 284 | Default value : 0 |
---|
| 285 | |
---|
| 286 | |
---|
| 287 | |
---|
| 288 | Command /run/particle/setCut |
---|
| 289 | Guidance : |
---|
| 290 | Set default cut value |
---|
| 291 | This command is equivallent to /run/setCut command. |
---|
| 292 | This command is kept for backward compatibility. |
---|
| 293 | Range of parameters : cut >0.0 |
---|
| 294 | |
---|
| 295 | Parameter : cut |
---|
| 296 | Parameter type : d |
---|
| 297 | Omittable : False |
---|
| 298 | Default value : 1 |
---|
| 299 | |
---|
| 300 | Parameter : Unit |
---|
| 301 | Parameter type : s |
---|
| 302 | Omittable : True |
---|
| 303 | Default value : mm |
---|
| 304 | Candidates : pc km m cm mm mum nm Ang fm parsec kilometer meter centimeter millimeter micrometer nanometer angstrom fermi |
---|
| 305 | |
---|
| 306 | |
---|
| 307 | |
---|
| 308 | Command /run/particle/dumpList |
---|
| 309 | Guidance : |
---|
| 310 | Dump List of particles in G4VUserPhysicsList. |
---|
| 311 | |
---|
| 312 | |
---|
| 313 | |
---|
| 314 | Command /run/particle/addProcManager |
---|
| 315 | Guidance : |
---|
| 316 | add process manager to specified particle type |
---|
| 317 | |
---|
| 318 | Parameter : particleType |
---|
| 319 | Parameter type : s |
---|
| 320 | Omittable : True |
---|
| 321 | |
---|
| 322 | |
---|
| 323 | |
---|
| 324 | Command /run/particle/buildPhysicsTable |
---|
| 325 | Guidance : |
---|
| 326 | build physics table of specified particle type |
---|
| 327 | |
---|
| 328 | Parameter : particleType |
---|
| 329 | Parameter type : s |
---|
| 330 | Omittable : True |
---|
| 331 | |
---|
| 332 | |
---|
| 333 | |
---|
| 334 | Command /run/particle/storePhysicsTable |
---|
| 335 | Guidance : |
---|
| 336 | Store Physics Table |
---|
| 337 | Enter directory name |
---|
| 338 | |
---|
| 339 | Parameter : dirName |
---|
| 340 | Parameter type : s |
---|
| 341 | Omittable : True |
---|
| 342 | |
---|
| 343 | |
---|
| 344 | |
---|
| 345 | Command /run/particle/retrievePhysicsTable |
---|
| 346 | Guidance : |
---|
| 347 | Retrieve Physics Table |
---|
| 348 | Enter directory name or OFF to switch off |
---|
| 349 | |
---|
| 350 | Parameter : dirName |
---|
| 351 | Parameter type : s |
---|
| 352 | Omittable : True |
---|
| 353 | |
---|
| 354 | |
---|
| 355 | |
---|
| 356 | Command /run/particle/setStoredInAscii |
---|
| 357 | Guidance : |
---|
| 358 | Switch on/off ascii mode in store/retreive Physics Table |
---|
| 359 | Enter 0(binary) or 1(ascii) |
---|
| 360 | Range of parameters : ascii ==0 || ascii ==1 |
---|
| 361 | |
---|
| 362 | Parameter : ascii |
---|
| 363 | Parameter type : i |
---|
| 364 | Omittable : True |
---|
| 365 | Default value : 0 |
---|
| 366 | |
---|
| 367 | |
---|
| 368 | |
---|
| 369 | Command /run/particle/applyCuts |
---|
| 370 | Guidance : |
---|
| 371 | Set applyCuts flag for a particle. |
---|
| 372 | Some EM processes which do not have infrared divergence |
---|
| 373 | may generate gamma, e- and/or e+ with kinetic energies |
---|
| 374 | below the production threshold. By setting this flag, |
---|
| 375 | such secondaries below threshold are eliminated and |
---|
| 376 | kinetic energies of such secondaries are accumulated |
---|
| 377 | to the energy deposition of their mother. |
---|
| 378 | Note that 'applyCuts' makes sense only for gamma, |
---|
| 379 | e- and e+. If this command is issued for other particle, |
---|
| 380 | a warning message is displayed and the command is |
---|
| 381 | ignored. |
---|
| 382 | If particle name is 'all', this command affects on |
---|
| 383 | gamma, e- and e+. |
---|
| 384 | |
---|
| 385 | Parameter : Flag |
---|
| 386 | Parameter type : s |
---|
| 387 | Omittable : True |
---|
| 388 | Default value : true |
---|
| 389 | |
---|
| 390 | Parameter : Particle |
---|
| 391 | Parameter type : s |
---|
| 392 | Omittable : True |
---|
| 393 | Default value : all |
---|
| 394 | |
---|
| 395 | |
---|
| 396 | |
---|
| 397 | Command /run/particle/dumpCutValues |
---|
| 398 | Guidance : |
---|
| 399 | Dump a list of production threshold values in range and energy |
---|
| 400 | for all registered material-cuts-couples. |
---|
| 401 | Dumping a list takes place when you issue 'beamOn' and |
---|
| 402 | actual conversion tables from range to energy are available. |
---|
| 403 | If you want a list 'immediately', use '/run/dumpRegion' for threshold |
---|
| 404 | list given in gange only. Also, '/run/dumpCouples' gives you the |
---|
| 405 | current list if you have already issued 'run/beamOn' at least once. |
---|
| 406 | |
---|
| 407 | Parameter : particle |
---|
| 408 | Parameter type : s |
---|
| 409 | Omittable : True |
---|
| 410 | Default value : all |
---|
| 411 | |
---|