[807] | 1 | # $Id: detector.py,v 1.3 2003/06/26 11:54:13 dressel Exp $ |
---|
| 2 | # ------------------------------------------------------------------- |
---|
| 3 | # GEANT4 tag $Name: $ |
---|
| 4 | # ------------------------------------------------------------------- |
---|
| 5 | # |
---|
| 6 | |
---|
| 7 | # A detector is either the of the "simple" or "ring" type. |
---|
| 8 | # the volumina of the "simple" detectors are the same at all |
---|
| 9 | # positions (00, 20, 40 cm off beam axis). The "ring" type detectors |
---|
| 10 | # have different volumina at the different positions. |
---|
| 11 | # For convinience a class Detector is provided to link a detector |
---|
| 12 | # position and it's volume. |
---|
| 13 | |
---|
| 14 | |
---|
| 15 | d00Volume = 1608.8 # volume of the 12.9 cm x 12.9 cm cyinder |
---|
| 16 | d20Volume = 20268.3 # volume of the ring at 20 cm |
---|
| 17 | d40Volume = 40536.6 # volume of the ring at 40 cm |
---|
| 18 | |
---|
| 19 | # map of distances to volumina for the 12.9 cm x 12.9 cm detectors |
---|
| 20 | SimpleDetectorVolume = {"00":d00Volume, "20":d00Volume, "40":d00Volume} |
---|
| 21 | # map of distances to volumina for ring detectors |
---|
| 22 | RingDetectorVolume = {"00":d00Volume, "20":d20Volume, "40":d40Volume} |
---|
| 23 | |
---|
| 24 | # map of detector type to distance-volumina map |
---|
| 25 | DetectorVolume = {"simple":SimpleDetectorVolume, |
---|
| 26 | "ring" :RingDetectorVolume} |
---|
| 27 | |
---|
| 28 | |
---|
| 29 | # the area of the beam pipe needed for scaling |
---|
| 30 | beamPipeArea = 93.31 |
---|
| 31 | |
---|
| 32 | # the source detector volume: beamPipeArea * 0.1 cm |
---|
| 33 | sourceDetectorVolume = 9.33 |
---|
| 34 | |
---|
| 35 | # source flux from the TIARA paper |
---|
| 36 | Fexp43_Coli = 1.76E+04 |
---|
| 37 | Fexp43 = 1.94E+04 |
---|
| 38 | Fexp68_Coli = 2.04E+04 |
---|
| 39 | Fexp68 = 2.46E+04 |
---|
| 40 | |
---|
| 41 | |
---|
| 42 | |
---|
| 43 | class Detector(object): |
---|
| 44 | "Distance and volume of a Detector." |
---|
| 45 | def __init__(self, dist, detType): |
---|
| 46 | self.name = dist |
---|
| 47 | self.volume = DetectorVolume[detType][dist] |
---|
| 48 | |
---|
| 49 | |
---|
| 50 | |
---|
| 51 | |
---|
| 52 | |
---|
| 53 | # function to calculate the scale factor |
---|
| 54 | |
---|
| 55 | def detScale(ngen, energy, coli): |
---|
| 56 | """Detrmine scale. |
---|
| 57 | |
---|
| 58 | Determine scale according to the number of generated neutrons, |
---|
| 59 | the proton beam energy. If coli == 1, the flux at the |
---|
| 60 | colimator exit is used, else the flux at 401 cm is used. |
---|
| 61 | """ |
---|
| 62 | Asrc = beamPipeArea |
---|
| 63 | Fexp = 0 |
---|
| 64 | if energy == "43": |
---|
| 65 | if coli == 1: |
---|
| 66 | Fexp = Fexp43_Coli |
---|
| 67 | else: |
---|
| 68 | Fexp = Fexp43 |
---|
| 69 | else: |
---|
| 70 | if energy == "68": |
---|
| 71 | if coli == 1: |
---|
| 72 | Fexp = Fexp68_Coli |
---|
| 73 | else: |
---|
| 74 | Fexp = Fexp68 |
---|
| 75 | |
---|
| 76 | S = Fexp * Asrc / ngen |
---|
| 77 | |
---|
| 78 | return S |
---|
| 79 | |
---|
| 80 | |
---|