[1337] | 1 | $Id: README,v 1.5 2010/04/02 15:46:31 maire Exp $ |
---|
[807] | 2 | ------------------------------------------------------------------- |
---|
| 3 | |
---|
| 4 | ========================================================= |
---|
| 5 | Geant4 - an Object-Oriented Toolkit for Simulation in HEP |
---|
| 6 | ========================================================= |
---|
| 7 | |
---|
| 8 | TestEm13 |
---|
| 9 | -------- |
---|
| 10 | |
---|
| 11 | How to compute cross sections from the tramsmition coefficient |
---|
| 12 | ( see below, item Physics). |
---|
| 13 | |
---|
| 14 | 1- GEOMETRY DEFINITION |
---|
| 15 | |
---|
| 16 | It is a single box representing a layer of finite thickness of |
---|
| 17 | homogeneous material. |
---|
| 18 | Two parameters define the geometry : |
---|
| 19 | - the material of the box, |
---|
| 20 | - the (full) size of the box. |
---|
| 21 | |
---|
| 22 | The default geometry (1 cm of water) is constructed in |
---|
| 23 | DetectorConstruction, but the above parameters can be changed |
---|
| 24 | interactively via the commands defined in DetectorMessenger. |
---|
| 25 | |
---|
| 26 | 2- PHYSICS LIST |
---|
| 27 | |
---|
| 28 | The physics list contains the standard electromagnetic processes. |
---|
[1337] | 29 | In order not to introduce 'artificial' constraints on the step size, the |
---|
| 30 | multiple scattering is not instanciated, and all processes are |
---|
| 31 | registered as discrete : there is no continuous energy loss. |
---|
[807] | 32 | |
---|
| 33 | 3- AN EVENT : THE PRIMARY GENERATOR |
---|
| 34 | |
---|
| 35 | The primary kinematic consists of a single particle starting at the edge |
---|
| 36 | of the box. The type of the particle and its energy are set in |
---|
| 37 | PrimaryGeneratorAction (1 MeV gamma), and can be changed via the G4 |
---|
| 38 | build-in commands of ParticleGun class (see the macros provided with |
---|
| 39 | this example). |
---|
| 40 | |
---|
| 41 | 4- PHYSICS |
---|
| 42 | |
---|
| 43 | An event is killed at the first step of the incident paticle. |
---|
| 44 | Either the particle has interacted or is transmitted through the layer. |
---|
| 45 | The cross section, also called absorption coefficient, is computed from |
---|
| 46 | the rate of unaltered transmitted incident particles. |
---|
| 47 | |
---|
| 48 | The result is compared with the 'input' data, i.e. with the cross |
---|
| 49 | sections stored in the PhysicsTables and used by Geant4. |
---|
| 50 | |
---|
| 51 | A set of macros defining various run conditions are provided. |
---|
| 52 | The processes are actived/inactived in order to survey the processes |
---|
| 53 | individually. |
---|
| 54 | |
---|
| 55 | |
---|
| 56 | 6- VISUALIZATION |
---|
| 57 | |
---|
| 58 | The Visualization Manager is set in the main(). |
---|
| 59 | The initialisation of the drawing is done via the commands |
---|
| 60 | /vis/... in the macro vis.mac. To get visualisation: |
---|
| 61 | > /control/execute vis.mac |
---|
| 62 | |
---|
| 63 | The detector has a default view which is a longitudinal view of the |
---|
| 64 | box. |
---|
| 65 | |
---|
| 66 | The tracks are drawn at the end of event, and erased at the end of run. |
---|
| 67 | |
---|
| 68 | 7- HOW TO START ? |
---|
| 69 | |
---|
| 70 | compile and link to generate an executable |
---|
| 71 | % cd geant4/examples/extended/electromagnetic/TestEm13 |
---|
| 72 | % gmake |
---|
| 73 | |
---|
| 74 | execute TestEm13 in 'batch' mode from macro files : |
---|
| 75 | % TestEm13 compt.mac |
---|
| 76 | |
---|
| 77 | execute TestEm13 in 'interactive mode' with visualization : |
---|
| 78 | % TestEm13 |
---|
| 79 | Idle> control/execute vis.mac |
---|
| 80 | .... |
---|
| 81 | Idle> type your commands |
---|
| 82 | .... |
---|
| 83 | Idle> exit |
---|
| 84 | |
---|