$Id: README,v 1.15 2009/11/20 16:22:14 gcosmo Exp $ ------------------------------------------------------------------- ========================================================= Geant4 - an Object-Oriented Toolkit for Simulation in HEP ========================================================= Examples module --------------- This module collects three sets of user examples aimed to demonstrate to the user how to make correct use of the GEANT4 toolkit by implementing in a correct way those user-classes which the user is supposed to customize in order to define his/her own simulation setup. One set of examples is oriented to "novice" users and covering all possible general use-cases typical of an "application"-oriented kind of development. An "extended" set of examples require some additional libraries besides of Geant4. This set covers some specific use cases for actual detector simulation. An "advanced" set of examples covers the use-cases typical of a "toolkit"-oriented kind of development, where real complete applications for different simulation studies are provided; may require additional third party products to be built. Most of the examples can be run both in interactive and batch mode, and input macro files (*.in) and reference output files (*.out) are provided. Novice and most of the extended examples are considered part of the system testing suite for validation of the official releases of the GEANT4 toolkit. Novice examples and some of the extended and advanced examples are also used as "acceptance"-tests for the release process. Novice level examples ExampleN01 - Mandatory user classes - Demonstrates how Geant4 kernel works ExampleN02 - Simplified tracker geometry with uniform magnetic field - Electromagnetic processes ExampleN03 - Simplified calorimeter geometry - Electromagnetic processes - Various materials ExampleN04 - Simplified collider detector with a readout geometry - Full "ordinary" processes - PYTHIA primary events - Event filtering by stack ExampleN05 - Simplified BaBar calorimeter - EM shower parametrisation ExampleN06 - Optical photon processes ExampleN07 - Regions and parameterised materials Extended level examples analysis - Histogramming through the AIDA interface biasing - Examples of event biasing, scoring and reverse-MC electromagnetic - Specific EM physics simulation with histogramming errorpropagation - Use of the error propagation utility (Geant4e) eventgenerator - Applications using interface to HepMC exoticphysics - Exotic simulation applications (classical magnetic monopole, etc...) field - Specific simulation setups in magnetic field g3tog3 - Examples of usage of the g3tog4 converter tool geometry - Specific geometry examples and tools: OLAP tool for detection of overlapping geometries hadronic - Specific hadronic physics simulation with histogramming medical - Specific examples for medical physics applications optical - Examples of generic optical processes simulation setups parallel - Examples of event-level parallelism in Geant4 using the TOP-C distribution, and distributed runs through DIANE parameterisations - Examples for fast shower parameterisations according to specific models persistency - Persistency of geometry (GDML or ASCII) and simulation output radioactivedecay - Examples to simulate the decays of radioactive isotopes and induced radioactivity resulted from nuclear interactions runAndEvent - Examples to demonstrate how to connect the information between primary particles and hits and utilize user-information classes visualization - Specific visualization features and graphical customisations Advanced level examples air_shower - Simulation of the ULTRA detector for UV and charged particles detection in cosmic rays brachytherapy - Setup for brachytherapy Ir-192 HDR source composite_calorimeter - Test-beam simulation used in CMS against real data taken in 1996 in a CMS Hadron calorimeter test-beam at LHC gammaray_telescope - Simulation of a typical telescope for gamma ray analysis hadrontherapy - Simulation of a hadron therapy beam line human_phantom - Anthropomorphic phantoms (male and female) based on MIRD/ORNL model with geometry description derived from GDML persistent files lAr_calorimeter - Simulation of the Liquid Argon Calorimeter of the ATLAS Detector at LHC medical_linac - Simulation of energy deposit in a Phantom filled with water for a typical linac used for intensity modulated radiation therapy microbeam - Simulation of the cellular irradiation beam line installed on the AIFIRA electrostatic accelerator facility located at CENBG, France microdosimetry - Simulation of DNA physics processes with track of a 10 keV Helium+ (positive charge is +e) particle in liquid water. nanobeam - Simulation of the beam optics of the nanobeam line installed on the AIFIRA electrostatic accelerator facility located at CENBG, France. purging_magnet - Simulation of electrons traveling through a 3D magnetic field of a strong purging magnet used for treatment head in a medical environment radioprotection - Application for the evaluation of dose in astronauts, vehicle concepts and Moon surface habitat configurations, in a space radiation environment Rich - Rich Test Beam Simulation underground_physics - Setup of an underground dark matter experiment xray_fluorescence - Test beam to characterize the response function of an HPGe detector used to measure fluorescence emissions xray_telescope - Realistic simulation of an X-ray Telescope