1 | # config file for class FrontEndChip |
---|
2 | # $Id: FrontEndChip.cfg 1497 2005-02-15 19:15:54Z thea $ |
---|
3 | # |
---|
4 | # double hit resolution in ns, i.e. minimum time distance between two |
---|
5 | # photons that are resolved by DFEE |
---|
6 | FrontEndChip.TimeResolution = 10 |
---|
7 | # |
---|
8 | # nominal front end amplifier gain; do not change |
---|
9 | FrontEndChip.Gain = 1 |
---|
10 | # |
---|
11 | # analog input threshold; 6 micro-Amps are about 1/4 of pe |
---|
12 | FrontEndChip.Threshold = 54 # micro-amps |
---|
13 | # |
---|
14 | FrontEndChip.CounterThreshold = 5 # digital threshold |
---|
15 | # |
---|
16 | # spread in gain from channel to channel |
---|
17 | FrontEndChip.GainSpread = 0.05 # gain spread |
---|
18 | # |
---|
19 | # spread (non uniformity) of threshold value (micro-amps) |
---|
20 | # now set to 10% |
---|
21 | FrontEndChip.ThreshSpread = 5.4 # threshold spread, micro-amps |
---|
22 | |
---|
23 | # type of front end trigger |
---|
24 | # 1 = standard : digital threshold on each channel |
---|
25 | # 2 = standard + groups 2x2 |
---|
26 | # 3 = same as 2 with overlapped groups 2x2 |
---|
27 | FrontEndChip.TriggerGroups = 1 |
---|