= FEB proto 3 : Synchronization = [[TOC(inline)]] [[TracNav]] In the following, the green signal is the reference CROC Global clock signal (CROC quartz), the yellow signal is either the clock of the front-end board, the L0 or the read_command. Green is the trigger for the clock study, the yellow signal is the trigger when looking at the L0 and the Read Command. The time scale is 2ns. == Djitter Clock == Incoming clock signal taken at the input of the LVDS/unipolar convertor of the board (polarity minus) [[Image(clock2.bmp)]] Clock signal taken at the output of the clock buffer driver. [[Image(clock3.bmp)]] Clock signal taken at the output of the Delay chip for ADC 0. [[Image(clock4.bmp)]] Clock ADC 0 (polarity +). [[Image(clock5.bmp)]] Clock ADC 0 (polarity -). [[Image(clock6.bmp)]] == Djitter L0 == L0 signal at the output of the LVDS/unipolar convertor of the FEB. [[Image(L0_1.bmp)]] L0 signal at the output of the Sequencer : a large (~1ns) djitter appears. [[Image(L0_2.bmp)]] == Djitter Read Command == First RdCmd at the output of the Sequencer. The First RdCmd is used as the scope trigger. Large djitter wrt to the CROC clock. [[Image(rd_1.bmp)]] One of the next RdCmd (8?). We have both a djitter wrt the clock (green) but also wrt the first RdCmd still used as the trigger reference. Rd_Cmd have djitters amongs themselves -> no sampling at the output of the sequencer ? [[Image(rd_2.bmp)]]