| [387] | 1 | \section{MEMPHYS detector} | 
|---|
|  | 2 | \label{sec:MEMPHYSdet} | 
|---|
|  | 3 | \subsection{General considerations} | 
|---|
|  | 4 | % | 
|---|
|  | 5 | The 20 year long successful operation of the | 
|---|
|  | 6 | Super-Kamiokande detector has clearly | 
|---|
|  | 7 | demonstrated the capabilities and limitations of large water \v{C}erenkov | 
|---|
|  | 8 | detectors\,: | 
|---|
|  | 9 | \begin{itemize} | 
|---|
|  | 10 | \item This technique is by far the cheapest | 
|---|
|  | 11 | and the most stable to instrument a very large detector | 
|---|
|  | 12 | mass, as price is dominated by the photodetectors and their associated | 
|---|
|  | 13 | electronics (this price growing like the outer surface of the detector), | 
|---|
|  | 14 | while the active mass, made of water, is essentially free except for the | 
|---|
|  | 15 | purification system | 
|---|
|  | 16 | \item These detectors are mainly limited in size by the finite attenuation | 
|---|
|  | 17 | length of \v{C}erenkov light, found to be 80 meters at $\lambda = 400$~nm | 
|---|
|  | 18 | in Super-Kamiokande, and by the pressure of water on the photomultipliers at | 
|---|
|  | 19 | the bottom of the tank, which gives a practical limit of 80~m in height. | 
|---|
|  | 20 | At large depths, the maximal size of underground cavities actually limits | 
|---|
|  | 21 | relevant dimensions to about 70~m. | 
|---|
|  | 22 | \item The detection principle consists in measuring \v{C}erenkov rings produced | 
|---|
|  | 23 | by charged particles going faster than light in water. This has several | 
|---|
|  | 24 | consequences\,: | 
|---|
|  | 25 | \begin{enumerate} | 
|---|
|  | 26 | \item neutral particles and charged particles | 
|---|
|  | 27 | below \v{C}erenkov threshold are undetectable, so that some energy may | 
|---|
|  | 28 | be missing | 
|---|
|  | 29 | \item complicated topologies are difficult to handle, and in practice only | 
|---|
|  | 30 | events with less than 3 to 5 rings are efficiently reconstructed | 
|---|
|  | 31 | \item ring topology, based on their degree of fuzziness, allows to separate | 
|---|
|  | 32 | between electromagnetic (e, $\gamma$) rings and ($\mu$, $\pi$) rings | 
|---|
|  | 33 | \item the threshold in particle energy depends mainly on photocathode | 
|---|
|  | 34 | coverage and also on water purity (due to radioactive backgrounds, such as | 
|---|
|  | 35 | radon). Super-Kamiokande has achieved an energy threshold of 5 MeV with | 
|---|
|  | 36 | 40\% cathode coverage | 
|---|
|  | 37 | \item due to points 1 and 2, water \v{C}erenkov detectors are not suited to | 
|---|
|  | 38 | measure high energy neutrino interactions, as more rings and more undetectable | 
|---|
|  | 39 | particles are produced. A further limitation comes from the confusion between | 
|---|
|  | 40 | single electron or gamma rings and high energy $\pi^0$'s giving 2 overlapping | 
|---|
|  | 41 | rings. In practice water \v{C}erenkov's stay excellent neutrino detectors | 
|---|
|  | 42 | for energies below 1 (may be 2) GeV, when interactions are mostly quasi-elastic | 
|---|
|  | 43 | and the 2 rings from $\pi^0$ well separated. | 
|---|
|  | 44 | \end{enumerate} | 
|---|
|  | 45 | \end{itemize} | 
|---|
|  | 46 | %%%%%%%%%%%%%%%%%%%%%%%%%%% | 
|---|
|  | 47 | \subsection{Detector design} | 
|---|
|  | 48 | %%%%%%%%%%%%%%%%%%%%%%%%%%%% | 
|---|
|  | 49 | Three detector designs are being carried out worldwide, | 
|---|
|  | 50 | namely Hyper-Kamiokande \cite{uno} in Japan, | 
|---|
|  | 51 | UNO \cite{hyperk} in the USA  and the present project MEMPHYS in Europe (Fig.~\ref{fig:Phys-MEMPHYSdetector}) \cite{deBellefon:2006vq}. | 
|---|
|  | 52 | All of them are rather mild extrapolations of Super-Kamiokande, and rely on the | 
|---|
|  | 53 | expertise acquired after 20 years of operation of this detector. | 
|---|
|  | 54 | Their main characteristics are summarized in table~\ref{WC:tab-1}. | 
|---|
|  | 55 | % | 
|---|
|  | 56 | % | 
|---|
|  | 57 | \begin{figure} | 
|---|
|  | 58 | \centering | 
|---|
|  | 59 | \includegraphics[width=0.45\textwidth]{MEMPHYS.eps} | 
|---|
|  | 60 | \caption{\label{fig:Phys-MEMPHYSdetector}Sketch of the MEMPHYS detector under the Fréjus mountain (Europe).} | 
|---|
|  | 61 | \end{figure} | 
|---|
|  | 62 | % | 
|---|
|  | 63 | \begin{sidewaystable} | 
|---|
|  | 64 | \centering | 
|---|
|  | 65 | % | 
|---|
|  | 66 | \begin{tabular}{rccc} | 
|---|
|  | 67 | \hline\noalign{\smallskip} | 
|---|
|  | 68 | Parameters                  &        \textbf{UNO} (USA)            & | 
|---|
|  | 69 | \textbf{HyperK} (Japan)          &      \textbf{MEMPHYS} (Europe)\\ | 
|---|
|  | 70 | \noalign{\smallskip}\hline\noalign{\smallskip} | 
|---|
|  | 71 | \multicolumn{4}{l}{\textbf{Underground laboratory}}  \\ | 
|---|
|  | 72 | location   &   Henderson / Homestake      &   Tochibora    & Fr\'ejus \\ | 
|---|
|  | 73 | depth (m.e.w.)  &    4500/4800                 & | 
|---|
|  | 74 | 1500                  &        4800  \\ | 
|---|
|  | 75 | Long Base Line (km)   & $1480\div2760$ / $1280\div2530$ & 290    &   130 \\ | 
|---|
|  | 76 | & FermiLab$\div$BNL       & JAERI         &   CERN \\ | 
|---|
|  | 77 | \noalign{\smallskip}\hline\noalign{\smallskip} | 
|---|
|  | 78 | \multicolumn{4}{l}{\textbf{Detector dimensions}}          \\ | 
|---|
|  | 79 | type              & 3 cubic compartments   & 2 twin tunnels  & $3\div5$ | 
|---|
|  | 80 | shafts\\ | 
|---|
|  | 81 | &                        & 5 compartments  &           \\ | 
|---|
|  | 82 | dimensions            & $3\times (60\times60\times60)\mathrm{m}^3$ | 
|---|
|  | 83 | & | 
|---|
|  | 84 | $2\times 5 \times (\phi=43\mathrm{m} \times L=50\mathrm{m})$       & | 
|---|
|  | 85 | $(3\div5)\times(\phi=65\mathrm{m} \times H=65\mathrm{m}) $ \\ | 
|---|
|  | 86 | fiducial mass (kt)& 440                          &       550 | 
|---|
|  | 87 | & $440\div730$\\ | 
|---|
|  | 88 | \noalign{\smallskip}\hline\noalign{\smallskip} | 
|---|
|  | 89 | \multicolumn{4}{l}{\textbf{Photodetectors}}          \\ | 
|---|
|  | 90 | type   & 20" PMT              & 13" H(A)PD           & 12" PMT | 
|---|
|  | 91 | \\ | 
|---|
|  | 92 | number (internal detector)     & 57,000      & 20,000 per compartment | 
|---|
|  | 93 | & 81,000 per shaft (Inner Vol.) \\ | 
|---|
|  | 94 | surface coverage & 40\% (1/3) \& 10\% (2/3) & 40\%  & 30\%\ | 
|---|
|  | 95 |  | 
|---|
|  | 96 | \\ | 
|---|
|  | 97 | \noalign{\smallskip}\hline | 
|---|
|  | 98 | \end{tabular} | 
|---|
|  | 99 | % | 
|---|
|  | 100 | \caption{\label{WC:tab-1} | 
|---|
|  | 101 | \it Some basic parameters of the three Water \v{C}erenkov | 
|---|
|  | 102 | detector baseline designs. An option is to fill one tank of MEMPHYS with Gadolinium (0.2\% Gd Cl$_3$).} | 
|---|
|  | 103 | \end{sidewaystable} | 
|---|
|  | 104 |  | 
|---|
|  | 105 | These 3 projects aim at a fiducial mass around half a megaton, taking into | 
|---|
|  | 106 | account the necessity to have a veto volume on the edge of the detector, 1 to 2 | 
|---|
|  | 107 | meters thick, plus a minimal distance of about 2 meters between photodetectors | 
|---|
|  | 108 | and interaction vertices, leaving some space for ring development. | 
|---|
|  | 109 | The main differences between the 3 projects lie in the geometry | 
|---|
|  | 110 | of the cavities (tunnel shape for Hyper-Kamiokande, shafts for MEMPHYS, | 
|---|
|  | 111 | intermediate with 3 cubic modules for UNO), and the photocathode coverage, | 
|---|
|  | 112 | similar to Super-Kamiokande for Hyper-Kamiokande | 
|---|
|  | 113 | and MEMPHYS, while UNO keeps this | 
|---|
|  | 114 | coverage on only 1 cubic detector, while the 2 others have only 10\% coverage | 
|---|
|  | 115 | for cost reasons. Another important parameter is the rock overburden, similar | 
|---|
|  | 116 | for UNO and MEMPHYS (4800~mwe), but smaller for Hyper-Kamiokande (1500~mwe), | 
|---|
|  | 117 | which might be a limiting factor for low energy physics, due to spallation | 
|---|
|  | 118 | products and fast neutrons produced by cosmic muons, more | 
|---|
|  | 119 | abundant by 2 orders of magnitude (see figure~\ref{muonflux}). | 
|---|
|  | 120 |  | 
|---|
|  | 121 | \begin{figure}[htb] | 
|---|
|  | 122 | \centerline{\epsfig{figure=muonflux_red.eps,width=8cm}} | 
|---|
|  | 123 | \caption{\it Muon flux as a function of overburden. | 
|---|
|  | 124 | The Frejus site is indicated by "LSM".} | 
|---|
|  | 125 | \label{muonflux} | 
|---|
|  | 126 | \end{figure} | 
|---|
|  | 127 |  | 
|---|
|  | 128 |  | 
|---|
|  | 129 | The basic unit for MEMPHYS consists of a cylindrical detector module 65~meters | 
|---|
|  | 130 | in diameter and 65~meters high, which can be housed | 
|---|
|  | 131 | in a cylindrical cavity with 70~meter diameter and 80 meter height, as proven | 
|---|
|  | 132 | by the prestudy. This corresponds to a water mass of 215 kilotons, that is | 
|---|
|  | 133 | only 4 times the Super-Kamiokande detector. | 
|---|
|  | 134 | Conservatively substracting 2~m for the | 
|---|
|  | 135 | outer veto plus 2~m for the fiducial volume, this leaves us with a fiducial | 
|---|
|  | 136 | mass of 146 kilotons per module. The baseline design uses 3 modules, giving | 
|---|
|  | 137 | a total fiducial mass of 440 kilotons, like UNO, corresponding to factor | 
|---|
|  | 138 | 20 increase over Super-Kamiokande (4 modules would give 580 | 
|---|
|  | 139 | kiloton fiducial mass). The modular aspect is actually mandatory for | 
|---|
|  | 140 | maintenance reasons, so that at least 2 of the 3 modules would be active | 
|---|
|  | 141 | at any time, giving 100\% duty cycle for supernova explosions. Furthermore, | 
|---|
|  | 142 | it would offer the possibility to add Gadolinium in one of the modules, which | 
|---|
|  | 143 | has been advocated to improve diffuse supernova neutrino detection. | 
|---|
|  | 144 | We estimate an overall construction time of less than 10 years, and of course | 
|---|
|  | 145 | the first module could start physics during the completion of the two other | 
|---|
|  | 146 | modules. | 
|---|
|  | 147 | %%%%%%%%%%%%%%%%%%%%%%%%%%% | 
|---|
|  | 148 | \subsection{Photodetection} | 
|---|
|  | 149 | %%%%%%%%%%%%%%%%%%%%%%%%%%% | 
|---|
|  | 150 | The baseline photodetector choice is photomultipliers (PMT) as they have | 
|---|
|  | 151 | successfuly equipped the previous generation of large water \v{C}erenkov | 
|---|
|  | 152 | detectors and many other types of presently running detectors in HEP. The PMT | 
|---|
|  | 153 | density should be chosen to allow excellent sensitivity to a broad range | 
|---|
|  | 154 | of nucleon decays and neutrino physics while keeping the instrumentation costs | 
|---|
|  | 155 | under control. | 
|---|
|  | 156 |  | 
|---|
|  | 157 | Our goal for MEMPHYS is to reach in the whole detector | 
|---|
|  | 158 | the same energy threshold as Super-Kamiokande, | 
|---|
|  | 159 | that is 5 MeV, important for solar neutrino studies, for the proton decay into | 
|---|
|  | 160 | $K^+ \nu$ using the 6~MeV tag from $^{15}$N desexcitation, and also very useful | 
|---|
|  | 161 | for SN explosions, since the measurement of the $\nu_{\mu}$ and $\nu_{\tau}$ | 
|---|
|  | 162 | fluxes could be achieved using the neutral current excitation of Oxygen. | 
|---|
|  | 163 |  | 
|---|
|  | 164 | Our first approach was to consider 20" Hamamatsu tubes as used by | 
|---|
|  | 165 | Super-Kamiokande, but the cost for 40\% coverage becomes prohibitive, as these | 
|---|
|  | 166 | tubes are manually blown by specially trained people, which makes them very | 
|---|
|  | 167 | expensive. Following a suggestion presented at the NNN05 conference by Photonis | 
|---|
|  | 168 | company, we have considered the possibility of using instead 12" PMT's, which | 
|---|
|  | 169 | can be automatically manufactured and have better characteristics | 
|---|
|  | 170 | compared to 20" tubes\,: quantum efficiency (24\% vs 20\%), collection | 
|---|
|  | 171 | efficiency (70\% vs 60\%), risetime (5~ns vs 10~ns), jitter (2.4~ns vs 5.5~ns). | 
|---|
|  | 172 | Based on these numbers, 30\% coverage with 12" PMT's would give the same number | 
|---|
|  | 173 | of photoelectrons per MeV as a 40\% coverage with 20" tubes. Taking into | 
|---|
|  | 174 | account the ratio of photocathodes (615~cm$^2$ vs 1660~cm$^2$), this implies | 
|---|
|  | 175 | that going from 20" tubes to twice as many 12" tubes will give the same | 
|---|
|  | 176 | detected light, with a bonus on time resolution and on pixel locations. If the dark | 
|---|
|  | 177 | current of better photocathodes does not increase dramatically the trigger rate, | 
|---|
|  | 178 | we can expect MEMPHYS performances be at least as good as Super-Kamiokande. | 
|---|
|  | 179 | A GEANT4 based Monte Carlo is under development to quantify the effective | 
|---|
|  | 180 | gain. Pricewise, each 20" PMT costing 2500 Euros | 
|---|
|  | 181 | is replaced by 2 12" PMT's costing 800 Euros each. | 
|---|
|  | 182 | The only caveat is to make sure that the savings on PMT's are not | 
|---|
|  | 183 | cancelled by the doubling of electronic channels. An R\&D on electronics | 
|---|
|  | 184 | integration is presently underway (see Sec. \ref{sec:photo}). | 
|---|
|  | 185 | %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% | 
|---|
|  | 186 | \subsection{Photomultiplier tests} | 
|---|
|  | 187 | %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% | 
|---|
|  | 188 | A joint R\&D program between Photonis company and French laboratories has been | 
|---|
|  | 189 | launched to test the quality of the 12" PMTs in the foreseen conditions of | 
|---|
|  | 190 | deep water depth, and to make a realistic | 
|---|
|  | 191 | market model for the production of about 250,000 PMTs that would be necessary | 
|---|
|  | 192 | to get the 30\% geometrical coverage. | 
|---|
|  | 193 |  | 
|---|
|  | 194 | In parallel, studies on new photo-sensors have been launched. | 
|---|
|  | 195 | The aim is to reduce cost, while improving production rate and performance, as | 
|---|
|  | 196 | it is essential | 
|---|
|  | 197 | to achieve the long term stability and reliability which is proven for PMTs. | 
|---|
|  | 198 | Hybrid photosensors (HPD) could be a solution\,: | 
|---|
|  | 199 | the principle has been proven by ICRR and Hamamatsu with a 5" HPD prototype. | 
|---|
|  | 200 | Successful results from tests of an 13" | 
|---|
|  | 201 | prototype operated with 12 kV are now available, | 
|---|
|  | 202 | showing a $3 \cdot 10^4$ gain, good single photon sensitivity, | 
|---|
|  | 203 | 0.8 ns time resolution and a satisfactory gain and | 
|---|
|  | 204 | timing uniformity over the photo-cathode area. | 
|---|
|  | 205 | The development of HPD has also been initiated in Europe, | 
|---|
|  | 206 | in collaboration with Photonis. | 
|---|
|  | 207 | %%%%%%%%%%%%%%%%%% | 
|---|
|  | 208 | \subsection{Smart-photodetector electronics} | 
|---|
|  | 209 | \label{sec:photo} | 
|---|
|  | 210 | %%%%%%%%%%%%%%%%%%% | 
|---|
|  | 211 | The coverage of large areas (around 17,500 m$^2$ for MEMPHYS) with | 
|---|
|  | 212 | photodetectors at lowest cost implies a readout integrated electronics | 
|---|
|  | 213 | circuit (called ASIC). This makes it possible to integrate: high-speed | 
|---|
|  | 214 | discriminator on the single photoelectron (pe), the | 
|---|
|  | 215 | digitisation of the charge on 12 bits ADC to provide numerical signals | 
|---|
|  | 216 | on a large dynamical range (200~pe), the digitisation of time on 12 | 
|---|
|  | 217 | bits TDC to provide time information with a precision of 1~ns, and | 
|---|
|  | 218 | channel-to-channel gain adjustment to homogenize the response of the | 
|---|
|  | 219 | photomultipliers and to thus use a common high voltage. Such an ASIC | 
|---|
|  | 220 | for readout electronics allows moreover a strong reduction of the | 
|---|
|  | 221 | costs, as well as external components (high-voltage units, cables of | 
|---|
|  | 222 | great quality...) since the electronics and the High Voltage may be | 
|---|
|  | 223 | put as close as possible to the PMTs and the generated numerical | 
|---|
|  | 224 | signals are directly usable by trigger logical units and | 
|---|
|  | 225 | the data acquisition computers (Fig.~\ref{fig:MEMPHYSPMTS}). | 
|---|
|  | 226 | % | 
|---|
|  | 227 |  | 
|---|
|  | 228 | The main difficulty in associating very fast analog electronics and | 
|---|
|  | 229 | digitization on a broad dynamic range does not make it possible yet to | 
|---|
|  | 230 | integrate all these functions in only one integrated circuit, but | 
|---|
|  | 231 | certain parts were already developed separately as for example in the | 
|---|
|  | 232 | OPERA Read Out Channel \cite{Lucotte:2004mi} | 
|---|
|  | 233 | (Fig.~\ref{fig:OPERAROC}). The evolution of integrated technologies, | 
|---|
|  | 234 | in particular BiCMOS SiGe 0.35$\mu$m, now make it possible to consider | 
|---|
|  | 235 | such circuits and has triggered a new campaign of research and | 
|---|
|  | 236 | development. | 
|---|
|  | 237 |  | 
|---|
|  | 238 | \begin{figure}[htb] | 
|---|
|  | 239 | \begin{minipage}[c]{0.44\textwidth} | 
|---|
|  | 240 | \centering | 
|---|
|  | 241 | \includegraphics[width=0.85\textwidth]{ModuleArriere.eps} | 
|---|
|  | 242 | \caption{\label{fig:MEMPHYSPMTS} | 
|---|
|  | 243 | \it Sketch of a possible photosensor basic module composed of a matrix | 
|---|
|  | 244 | of $4\times4$ 12" PMTs with the electronic box containing the High | 
|---|
|  | 245 | Voltage unit and the Readout chip.} | 
|---|
|  | 246 | \end{minipage} | 
|---|
|  | 247 | % | 
|---|
|  | 248 | \begin{minipage}[c]{0.04\textwidth} | 
|---|
|  | 249 | ~ | 
|---|
|  | 250 | \end{minipage} | 
|---|
|  | 251 | % | 
|---|
|  | 252 | \begin{minipage}[c]{0.44\textwidth} | 
|---|
|  | 253 | \centering | 
|---|
|  | 254 | \includegraphics[width=\textwidth]{electronic.eps} | 
|---|
|  | 255 | \caption{\label{fig:OPERAROC} | 
|---|
|  | 256 | \it Sketch of the existing Read Out electronics developed for the | 
|---|
|  | 257 | OPERA Target Tracker and that is intented to be extended for MEMPHYS | 
|---|
|  | 258 | by integrating the ADC and TDC.} | 
|---|
|  | 259 | \end{minipage} | 
|---|
|  | 260 | \end{figure} | 
|---|
|  | 261 | % | 
|---|
|  | 262 |  | 
|---|
|  | 263 |  | 
|---|
|  | 264 |  | 
|---|
|  | 265 |  | 
|---|