Changes between Version 6 and Version 7 of CROCproto3
- Timestamp:
- Jun 7, 2006, 6:37:16 PM (18 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
CROCproto3
v6 v7 5 5 [[TOC(inline)]] 6 6 7 == Problem identified ==7 == Problems identified == 8 8 9 9 * Inversion of the SDA and SCL signal between the LV010 (near RJ45 of the front face of the CROC) and the SPECS Mezzanine connector 10 10 11 11 * Adaptation of the SPECS Signal in the case when the SPECS Mezzanine is simply a repeater 12 13 * Polarisation of the 2 drivers going to the backplane for specs sda- signals. the sda- is not well polarised and the V divider on the +sda simply changes the common mode. This leads to a bad pulse when the command to the driver is released. The sda- pin has to be polarised to GND with for example a 5k resistor. Then the sda+/- signals are well polarised. 14 15 12 16 13 17 == CROC proto 3 : Fabrication status ==